跳到主要导航 跳到搜索 跳到主要内容

Fault tolerant control for steam generators in nuclear power plant

  • Zhi Hong Deng*
  • , Xiao Cheng Shi
  • , Guo Qing Xia
  • , Ming Yu Fu
  • *此作品的通讯作者
  • Harbin Engineering University

科研成果: 期刊稿件文章同行评审

摘要

Based on the nonlinear system with stochastic noise, a bank of extended Kalman filters is used to estimate the state of sensors. It can real-time detect and isolate the single sensor fault, and reconstruct the sensor output to keep steam generator water level stable. The simulation results show that the methodology of employing a bank of extended Kalman filters for steam generator fault tolerant control design is feasible.

源语言英语
页(从-至)107-111+116
期刊Hedongli Gongcheng/Nuclear Power Engineering
31
1
出版状态已出版 - 2月 2010
已对外发布

指纹

探究 'Fault tolerant control for steam generators in nuclear power plant' 的科研主题。它们共同构成独一无二的指纹。

引用此