跳到主要导航 跳到搜索 跳到主要内容

Failure of the plasma-sprayed coating of lanthanum hexaluminate

  • X. Q. Cao*
  • , Y. F. Zhang
  • , J. F. Zhang
  • , X. H. Zhong
  • , Y. Wang
  • , H. M. Ma
  • , Z. H. Xu
  • , L. M. He
  • , F. Lu
  • *此作品的通讯作者

科研成果: 期刊稿件文章同行评审

摘要

Lanthanum magnesium hexaluminate (LaMgAl11O19, LMA) is an attractive material for thermal barrier coatings (TBCs), and the failure of its coating was studied in this work by thermal cycling, X-ray diffraction, dilatometric measurement and thermal gravimetric-differential thermal analysis. The dilatometric measurement indicates that even though the bulk material of LMA has a higher sintering-resistance than the typical TBC material, i.e. yttria-stabilized zirconia (YSZ), the plasma sprayed coating of LMA has two serious contractions due to the re-crystallization of LMA and phase transitions of alumina. LMA has similar thermal expansion behaviour with alumina, leading to a good thermal expansion match between LMA and the thermally grown oxide layer. On the other hand, the plate-like structure of LMA not only results in a low thermal conductivity, low Young's modulus, but also a high stress tolerance, and these are believed to be the reasons for the long thermal cycling life of LMA coating.

源语言英语
页(从-至)1979-1986
页数8
期刊Journal of the European Ceramic Society
28
10
DOI
出版状态已出版 - 2008
已对外发布

指纹

探究 'Failure of the plasma-sprayed coating of lanthanum hexaluminate' 的科研主题。它们共同构成独一无二的指纹。

引用此