TY - JOUR
T1 - Experimental study on the thermoelectric performance of a thermoelectric generator integrated with a gravity heat pipe
AU - Zhao, Yulong
AU - Zuo, Ao
AU - Zhang, Hanxin
AU - Wang, Wei
AU - Ge, Minghui
N1 - Publisher Copyright:
© 2026 Elsevier Ltd.
PY - 2026/10
Y1 - 2026/10
N2 - A gravity heat pipe (GHP) - integrated thermoelectric generator (TEG) utilizes the superior thermal conductivity of the GHP to facilitate efficient thermal exchange between the heat source/sink and the thermoelectric modules, exhibiting greater thermoelectric conversion efficiency and considerable potential for practical applications. In this study, a GHP-TEG is developed, and the effects of heating heat flux and GHP inclination angle on the GHP-TEG performance are quantitatively investigated. The experimental results show that as the heating heat flux is increased from 4500 W/m2 to 10,500 W/m2, the GHP thermal resistance is reduced by 31.30%, accompanied by substantial improvements in both output power and thermoelectric conversion efficiency. At a heating heat flux of 10,500 W/m2, the system attains a maximum output power of 5.34 W and a thermoelectric efficiency of 2.54%. An increase in the GHP inclination angle leads to a reduction in its thermal resistance; however, owing to the relatively small contribution of the GHP thermal resistance to the overall thermal resistance, the inclination angle exerts a limited influence on thermoelectric performance. At a heating heat flux of 7500 W/m2, the generator achieves its maximum output power at an inclination angle of 90°, which is 7.34% higher than that recorded at 5°. The findings of this study offer experimental support for the optimization of GHP-TEG structures and operating strategies, and provide a useful reference for enhancing the efficiency of waste heat recovery systems.
AB - A gravity heat pipe (GHP) - integrated thermoelectric generator (TEG) utilizes the superior thermal conductivity of the GHP to facilitate efficient thermal exchange between the heat source/sink and the thermoelectric modules, exhibiting greater thermoelectric conversion efficiency and considerable potential for practical applications. In this study, a GHP-TEG is developed, and the effects of heating heat flux and GHP inclination angle on the GHP-TEG performance are quantitatively investigated. The experimental results show that as the heating heat flux is increased from 4500 W/m2 to 10,500 W/m2, the GHP thermal resistance is reduced by 31.30%, accompanied by substantial improvements in both output power and thermoelectric conversion efficiency. At a heating heat flux of 10,500 W/m2, the system attains a maximum output power of 5.34 W and a thermoelectric efficiency of 2.54%. An increase in the GHP inclination angle leads to a reduction in its thermal resistance; however, owing to the relatively small contribution of the GHP thermal resistance to the overall thermal resistance, the inclination angle exerts a limited influence on thermoelectric performance. At a heating heat flux of 7500 W/m2, the generator achieves its maximum output power at an inclination angle of 90°, which is 7.34% higher than that recorded at 5°. The findings of this study offer experimental support for the optimization of GHP-TEG structures and operating strategies, and provide a useful reference for enhancing the efficiency of waste heat recovery systems.
KW - Exergy analysis
KW - Gravity heat pipe
KW - Inclination angle
KW - Thermal resistance
KW - Thermoelectric generator
UR - https://www.scopus.com/pages/publications/105049788985
U2 - 10.1016/j.applthermaleng.2026.133194
DO - 10.1016/j.applthermaleng.2026.133194
M3 - Article
AN - SCOPUS:105049788985
SN - 1359-4311
VL - 306
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 133194
ER -