跳到主要导航 跳到搜索 跳到主要内容

Experimental study on a cryogenic loop heat pipe with high heat capacity

  • Ya'Nan Zhao
  • , Tao Yan*
  • , Jingtao Liang
  • *此作品的通讯作者

科研成果: 期刊稿件文章同行评审

摘要

Cryogenic loop heat pipes (CLHPs) are efficient heat transfer devices based on two-phase flow. Loop heat pipes for room temperature applications have achieved satisfactory thermal control functions with the benefits of no mechanical moving part, vibration isolation, thermal insulation, long heat transport distance and so on. While there exist many problems for low temperature applications of loop heat pipes, such as limited heat transport capacity, which could not meet the increasing requirement of instrument heat dissipation. This paper presents an advanced CLHP operating at liquid-nitrogen temperature range. An improved condenser structure is introduced to the CLHP, which greatly reduces the flow resistance and increases the cooling capability of the condenser. Many experiments have been carried out on the CLHP prototype for performance test, and one set of the experimental results with a 3.2 MPa fill pressure at room temperature is presented in this paper. It is shown that the advanced CLHP prototype can be operated reliably with a high heat transfer capacity up to 41 W and a limited temperature difference of 6 K across a 0.48 m transport distance.

源语言英语
页(从-至)3304-3308
页数5
期刊International Journal of Heat and Mass Transfer
54
15-16
DOI
出版状态已出版 - 7月 2011
已对外发布

指纹

探究 'Experimental study on a cryogenic loop heat pipe with high heat capacity' 的科研主题。它们共同构成独一无二的指纹。

引用此