TY - GEN
T1 - Effect of structurally-induced lateral confinement on split Hopkinson pressure bar test specimens of concrete-like materials
AU - Flores-Johnson, E. A.
AU - Li, Q. M.
N1 - Publisher Copyright:
© 2015 Owned by the authors, published by EDP Sciences.
PY - 2015/9/7
Y1 - 2015/9/7
N2 - In dynamic testing of concrete-like materials, there is a need in distinguishing structural effects from genuine strain-rate effects. In this paper, this generic problem is studied by numerical simulations based on a phenomenological material model available in the commercial finite element (FE) code Abaqus. The numerical results show that the increase of the dynamic increase factor (DIF) with the increase of strain-rate in concrete-like materials in a Split Hopkinson Pressure Bar (SHPB) test is a phenomenon related not only to material strain-rate effects but also to structural effects. It was found that dilation, surface friction and lateral inertia cause lateral confinement, which enhances DIF when the strain-rate is greater than a transition strain-rate in the order of 102 s-1. Although, genuine strain-rate effect may exist as suggested by meso-scale simulations in previous investigations, the findings in this study show that structural effects have a significant contribution to the increase of DIF, and therefore, it is necessary to correctly calibrate existing phenomenological models and interpret the results obtained from split Hopkinson pressure bar (SHPB) tests.
AB - In dynamic testing of concrete-like materials, there is a need in distinguishing structural effects from genuine strain-rate effects. In this paper, this generic problem is studied by numerical simulations based on a phenomenological material model available in the commercial finite element (FE) code Abaqus. The numerical results show that the increase of the dynamic increase factor (DIF) with the increase of strain-rate in concrete-like materials in a Split Hopkinson Pressure Bar (SHPB) test is a phenomenon related not only to material strain-rate effects but also to structural effects. It was found that dilation, surface friction and lateral inertia cause lateral confinement, which enhances DIF when the strain-rate is greater than a transition strain-rate in the order of 102 s-1. Although, genuine strain-rate effect may exist as suggested by meso-scale simulations in previous investigations, the findings in this study show that structural effects have a significant contribution to the increase of DIF, and therefore, it is necessary to correctly calibrate existing phenomenological models and interpret the results obtained from split Hopkinson pressure bar (SHPB) tests.
UR - https://www.scopus.com/pages/publications/84958073955
U2 - 10.1051/epjconf/20159404031
DO - 10.1051/epjconf/20159404031
M3 - Conference contribution
AN - SCOPUS:84958073955
T3 - EPJ Web of Conferences
BT - DYMAT 2015 - 11th International Conference on the Mechanical and Physical Behaviour of Materials Under Dynamic Loading
A2 - Cadoni, Ezio
PB - EDP Sciences
T2 - 11th International Conference on the Mechanical and Physical Behaviour of Materials Under Dynamic Loading, DYMAT 2015
Y2 - 7 September 2015 through 11 September 2015
ER -