跳到主要导航 跳到搜索 跳到主要内容

Effect of electrode number on the operating range of capacitance proximity fuze

  • Xin Zhang*
  • , Zhanzhong Cui
  • , Lixin Xu
  • *此作品的通讯作者
  • Beijing Institute of Technology

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

To define which detect electrode type between two elecrodes and three elecrodes can extend the operating range of capacitance proximity fuze, took sphere as elecrode, and equivalent sphere models of two and three elecrodes were established. The mirror method and Ansoft Maxwell microsoft were used to calculate the capacitance value of the model, then got the figure of capacitance-missile target distance. Based on this, Matlab was used to calculate the oscillator frequency, and got the fiure of frequency-missile target distance. According to the capacitance value and oscillator frequency, got the figure of capacitance changes-missile target distance and the figure of frequency changes- missile target distance. By comparing the frequency changes of the two electrodes with the changes of the three electrodes, draw the conclusion that the changes of three electrodes type are bigger than the ones of two electrodes type, so three electrodes type is better than the the two electrodes type to extend the operating range.

源语言英语
页(从-至)98-103
页数6
期刊Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument
卷31
期8 SUPPL.
出版状态已出版 - 8月 2010
已对外发布是

学术指纹

探究 'Effect of electrode number on the operating range of capacitance proximity fuze' 的科研主题。它们共同构成独一无二的学术指纹。