T1 - Diffusion-Low-Rank Hybrid Reconstruction for Sparse-View Medical Imaging
AU - Deng, Zongyin
AU - Zhou, Qing
AU - Fang, Yuhao
AU - Wang, Zijian
AU - Lu, Yao
AU - Zhang, Ye
AU - Li, Chun
N1 - Publisher Copyright:
© 2025 IEEE.
PY - 2025
Y1 - 2025
N2 - This work presents TV-LoRA, a novel method for low-dose sparse-view CT reconstruction that combines a diffusion generative prior (NCSN++ with SDE modeling) and multi-regularization constraints, including anisotropic TV and nuclear norm (LoRA), within an ADMM framework. To address ill-posedness and texture loss under extremely sparse views, TV-LoRA integrates generative and physical constraints, and utilizes a 2D slice-based strategy with FFT acceleration and tensor-parallel optimization for efficient inference. Experiments on AAPM-2016, CTHD, and LIDC datasets with Nview = 8, 4, 2 show that TV-LoRA consistently surpasses benchmarks in SSIM, texture recovery, edge clarity, and artifact suppression, demonstrating strong robustness and generalizability. Ablation studies confirm the complementary effects of LoRA regularization and diffusion priors, while the FFT-PCG module provides a 4.5× speedup. Overall, Diffusion + TV-LoRA achieves high-fidelity, efficient 3D CT reconstruction and broad clinical applicability in low-dose, sparse-sampling scenarios.
AB - This work presents TV-LoRA, a novel method for low-dose sparse-view CT reconstruction that combines a diffusion generative prior (NCSN++ with SDE modeling) and multi-regularization constraints, including anisotropic TV and nuclear norm (LoRA), within an ADMM framework. To address ill-posedness and texture loss under extremely sparse views, TV-LoRA integrates generative and physical constraints, and utilizes a 2D slice-based strategy with FFT acceleration and tensor-parallel optimization for efficient inference. Experiments on AAPM-2016, CTHD, and LIDC datasets with Nview = 8, 4, 2 show that TV-LoRA consistently surpasses benchmarks in SSIM, texture recovery, edge clarity, and artifact suppression, demonstrating strong robustness and generalizability. Ablation studies confirm the complementary effects of LoRA regularization and diffusion priors, while the FFT-PCG module provides a 4.5× speedup. Overall, Diffusion + TV-LoRA achieves high-fidelity, efficient 3D CT reconstruction and broad clinical applicability in low-dose, sparse-sampling scenarios.
KW - ADMM
KW - Diffusion Model
KW - Image Reconstruction
KW - Inverse Problems
KW - Low-Rank Regularization
UR - https://www.scopus.com/pages/publications/105040979317
U2 - 10.1109/CAC67268.2025.11486875
DO - 10.1109/CAC67268.2025.11486875
M3 - Conference contribution
AN - SCOPUS:105040979317
T3 - Proceedings - 2025 China Automation Congress, CAC 2025
SP - 4803
EP - 4808
BT - Proceedings - 2025 China Automation Congress, CAC 2025
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2025 China Automation Congress, CAC 2025
Y2 - 26 September 2025 through 28 September 2025
ER -