跳到主要导航 跳到搜索 跳到主要内容

Detection and analysis of cerebral aneurysms based on X-ray rotational angiography - the CADA 2020 challenge

  • Matthias Ivantsits*
  • , Leonid Goubergrits
  • , Jan Martin Kuhnigk
  • , Markus Huellebrand
  • , Jan Bruening
  • , Tabea Kossen
  • , Boris Pfahringer
  • , Jens Schaller
  • , Andreas Spuler
  • , Titus Kuehne
  • , Yizhuan Jia
  • , Xuesong Li
  • , Suprosanna Shit
  • , Bjoern Menze
  • , Ziyu Su
  • , Jun Ma
  • , Ziwei Nie
  • , Kartik Jain
  • , Yanfei Liu
  • , Yi Lin
  • Anja Hennemuth
*此作品的通讯作者
  • Charité – Universitätsmedizin Berlin
  • Einstein Center Digital Future
  • Fraunhofer Institute for Digital Medicine
  • Helios Hospital Berlin-Buch
  • Deutsches Herzzentrum Berlin
  • German Centre for Cardiovascular Research
  • Mediclouds Medical Technology
  • Technical University of Munich
  • Beijing Institute of Technology
  • Nanjing University of Science and Technology
  • Nanjing University
  • University of Twente
  • Tencent
  • Shenzhen United Imaging Research Institute of Innovative Medical Equipment

科研成果: 期刊稿件短篇评述同行评审

摘要

The Cerebral Aneurysm Detection and Analysis (CADA) challenge was organized to support the development and benchmarking of algorithms for detecting, analyzing, and risk assessment of cerebral aneurysms in X-ray rotational angiography (3DRA) images. 109 anonymized 3DRA datasets were provided for training, and 22 additional datasets were used to test the algorithmic solutions. Cerebral aneurysm detection was assessed using the F2 score based on recall and precision, and the fit of the delivered bounding box was assessed using the distance to the aneurysm. The segmentation quality was measured using the Jaccard index and a combination of different surface distance measures. Systematic errors were analyzed using volume correlation and bias. Rupture risk assessment was evaluated using the F2 score. 158 participants from 22 countries registered for the CADA challenge. The U-Net-based detection solutions presented by the community show similar accuracy compared to experts (F2 score 0.92), with a small number of missed aneurysms with diameters smaller than 3.5 mm. In addition, the delineation of these structures, based on U-Net variations, is excellent, with a Jaccard score of 0.92. The rupture risk estimation methods achieved an F2 score of 0.71. The performance of the detection and segmentation solutions is equivalent to that of human experts. The best results are obtained in rupture risk estimation by combining different image-based, morphological, and computational fluid dynamic parameters using machine learning methods. Furthermore, we evaluated the best methods pipeline, from detecting and delineating the vessel dilations to estimating the risk of rupture. The chain of these methods achieves an F2-score of 0.70, which is comparable to applying the risk prediction to the ground-truth delineation (0.71).

源语言英语
期刊论文编号102333
期刊Medical Image Analysis
77
DOI
出版状态已出版 - 4月 2022

学术指纹

探究 'Detection and analysis of cerebral aneurysms based on X-ray rotational angiography - the CADA 2020 challenge' 的科研主题。它们共同构成独一无二的学术指纹。

引用此