摘要
The mass transfer plays a decisive role in screening and evaluation of amine solvents as well as in designing and scale-up of CO2 capture. The influence of different operating parameters on mass transfer processes in CO2 capture by EAE-1DMA2P amine solution was thoroughly investigated using a small-scale packed column. The mass transfer mechanism of EAE-1DMA2P amine solution in the capture of CO2 was discussed by determining both mass transfer control steps and the reaction region between CO2 and amine solvent, which provided a theoretical guidance for subsequent development of new solvents for large-scale applications. In addition, based on the experimental observations of KGav, a prediction model for KGav of EAE-1DMA2P composite amine solution was established by comparing two empirical models viz., Kohl-Riesenfeld-Astarita and Sheng of which Kohl-Riesenfeld-Astarita model provided a better fitting of the experimental results. The commonly used amine solvents and EAE-1DMA2P composite solvents were further compared and analyzed in terms of packed column size design and solvent consumption. The required packed column volume using EAE-1DMA2P composite solvent was only 4.95 m3, while the EAE-1DMA2P composite solvent has the smallest solvent consumption among all the solvents, indicating that this solvent has a lower operating cost than the other solvents, suggesting better industrial application.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 147918 |
| 期刊 | Chemical Engineering Journal |
| 卷 | 480 |
| DOI | |
| 出版状态 | 已出版 - 15 1月 2024 |
| 已对外发布 | 是 |
指纹
探究 'CO2 capture from flue gas using EAE-1DMA2P solvent in a packed column' 的科研主题。它们共同构成独一无二的指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver