TY - JOUR
T1 - Control strategy for input-series-output-series high-frequency AC-link inverters
AU - Sha, Deshang
AU - Xu, Guo
AU - Liao, Xiaozhong
PY - 2013
Y1 - 2013
N2 - This paper presents a control strategy for input-series-output-series (ISOS) modular inverters. Each module is a bidirectional high-frequency ac-link (HFACL) inverter composed of an HF inverter, an HF transformer followed by a cycloconverter. The relationship between input voltage sharing (IVS) and output voltage sharing (OVS) is revealed with a general load based on bidirectional ISOS inverter systems. To achieve IVS and OVS, a stable power sharing control strategy eliminating mandatory IVS loops is proposed. For individual modules, the common output voltage regulation loop output multiplies its magnitude compensator loop output to work as its pulse width modulation signal. The loop gain design is also presented. With the proposed control strategy, excellent IVS and OVS can be obtained not only during steady state but also during transients. The effectiveness of the proposed control strategy is verified by simulation and experimental results of a 2420-VA ISOS two HFACL inverters.
AB - This paper presents a control strategy for input-series-output-series (ISOS) modular inverters. Each module is a bidirectional high-frequency ac-link (HFACL) inverter composed of an HF inverter, an HF transformer followed by a cycloconverter. The relationship between input voltage sharing (IVS) and output voltage sharing (OVS) is revealed with a general load based on bidirectional ISOS inverter systems. To achieve IVS and OVS, a stable power sharing control strategy eliminating mandatory IVS loops is proposed. For individual modules, the common output voltage regulation loop output multiplies its magnitude compensator loop output to work as its pulse width modulation signal. The loop gain design is also presented. With the proposed control strategy, excellent IVS and OVS can be obtained not only during steady state but also during transients. The effectiveness of the proposed control strategy is verified by simulation and experimental results of a 2420-VA ISOS two HFACL inverters.
KW - High-frequency link inverter
KW - input voltage sharing
KW - input-series-output- series (ISOS)
KW - output voltage sharing
UR - https://www.scopus.com/pages/publications/84877877379
U2 - 10.1109/TPEL.2013.2246191
DO - 10.1109/TPEL.2013.2246191
M3 - Article
AN - SCOPUS:84877877379
SN - 0885-8993
VL - 28
SP - 5283
EP - 5292
JO - IEEE Transactions on Power Electronics
JF - IEEE Transactions on Power Electronics
IS - 11
M1 - 6466392
ER -