TY - JOUR
T1 - Beyond Photometric Consistency
T2 - Addressing Loss Insensitivity to Depth Noise in Endoscopic Estimation via Error Calibration
AU - Lu, Dawei
AU - Xiao, Deqiang
AU - Shao, Long
AU - Lin, Yucong
AU - Fan, Jingfan
AU - Ai, Danni
AU - Fu, Tianyu
AU - Wang, Yuanyuan
AU - Shao, Shuwei
AU - Li, Jingtao
AU - Song, Hong
AU - Yang, Jian
N1 - Publisher Copyright:
© 2013 IEEE.
PY - 2026
Y1 - 2026
N2 - Self-supervised monocular depth estimation in endoscopy is fundamentally constrained by the ill-posed nature of photometric supervision. In this work, we identify a critical yet overlooked cause of this ambiguity: the inherent insensitivity of photometric loss to depth noise. To overcome this intrinsic limitation, we propose Depth Error Calibration Learning (DECL), a two-stage framework that suppresses prediction variance and mitigates residual errors in self-supervised depth estimation. In Stage I (Variance Reduction), a cyclic depth generation strategy produces multiple depth hypotheses for the input image. The per-pixel empirical variance is quantified and integrated into a dedicated variance loss term, which penalizes inconsistent predictions and encourages the network to generate more stable and reliable depth estimates. In Stage II (Bias Calibration), an image-conditioned diffusion model refines the Stage-I depth prior and mitigates structured residuals through iterative denoising, thereby improving geometric accuracy and global consistency. Extensive experiments on three public endoscopic datasets demonstrate that DECL achieves consistent improvements over representative self-supervised monocular depth estimation methods under the evaluated protocols. Moreover, ablation studies on two representative backbones indicate that DECL is not restricted to a single network implementation, while broader validation on additional backbone families remains necessary.
AB - Self-supervised monocular depth estimation in endoscopy is fundamentally constrained by the ill-posed nature of photometric supervision. In this work, we identify a critical yet overlooked cause of this ambiguity: the inherent insensitivity of photometric loss to depth noise. To overcome this intrinsic limitation, we propose Depth Error Calibration Learning (DECL), a two-stage framework that suppresses prediction variance and mitigates residual errors in self-supervised depth estimation. In Stage I (Variance Reduction), a cyclic depth generation strategy produces multiple depth hypotheses for the input image. The per-pixel empirical variance is quantified and integrated into a dedicated variance loss term, which penalizes inconsistent predictions and encourages the network to generate more stable and reliable depth estimates. In Stage II (Bias Calibration), an image-conditioned diffusion model refines the Stage-I depth prior and mitigates structured residuals through iterative denoising, thereby improving geometric accuracy and global consistency. Extensive experiments on three public endoscopic datasets demonstrate that DECL achieves consistent improvements over representative self-supervised monocular depth estimation methods under the evaluated protocols. Moreover, ablation studies on two representative backbones indicate that DECL is not restricted to a single network implementation, while broader validation on additional backbone families remains necessary.
KW - Depth estimation
KW - diffusion model
KW - monocular endoscopic image
KW - self-supervised learning
UR - https://www.scopus.com/pages/publications/105050245363
U2 - 10.1109/JBHI.2026.3729759
DO - 10.1109/JBHI.2026.3729759
M3 - Article
C2 - 42678831
AN - SCOPUS:105050245363
SN - 2168-2194
JO - IEEE Journal of Biomedical and Health Informatics
JF - IEEE Journal of Biomedical and Health Informatics
ER -