Approach to feed-forward adaptive control for variable pump and valve controlled electro-hydraulic system

Baojiang Chen*, Bo Mo, Fan Cao

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

4 引用 (Scopus)

摘要

The variable pump makes the open loop gain change and decrease, the tracking control accuracy is difficult to be achieved by traditional feedback control A/O cascade control. Effective compensation to the change of open loop gain can be achieved with micro-controller and compound control methods. Using the MCS-96 chip technology, feedback control, feed-forward control and adaptive control principles, The chip computer feed-forward adaptive controller is developed, and the adaptive digital control to the system is realized and tested. The tests results show that the controller is the effective control method for the variable pump and valve controlled system.

源语言英语
页(从-至)217-220
页数4
期刊Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering
42
3
DOI
出版状态已出版 - 3月 2006

指纹

探究 'Approach to feed-forward adaptive control for variable pump and valve controlled electro-hydraulic system' 的科研主题。它们共同构成独一无二的指纹。

引用此