ANALYSIS AND SUPPRESSION OF ON-LOAD EXCITATION WINDING VOLTAGE PULSATING IN PARTITIONED-STATOR HYBRID-EXCITED SWITCHED-FLUX MACHINE

  • University of Sheffield

科研成果: 书/报告/会议事项章节 › 会议稿件 › 同行评审

摘要

Based on a hybrid-excited switched-flux machine having partitioned-stator (PS-HESFM), the on-load excitation winding voltage pulsating is analyzed and minimized in this paper. Different from the voltage pulsating under no-load, the effect of armature reaction on excitation winding voltage pulsating is taken into consideration in this paper. Two suppression methods, i.e., iron piece rotor inner and outer pole arcs pairing and uneven tooth distribution adopted and comparatively analyzed to suppress the on-load excitation winding voltage pulsating using the finite element (FE) method. It reveals that, by employing iron piece rotor inner and outer pole arcs pairing and uneven tooth distribution, the peak-to-peak excitation winding voltage pulsating at on-load is significantly reduced by 92.8% and 90.6%, respectively, albeit with the slight reduction of average on-load torque by 7.3% and 6.6%.

源语言英语
主期刊名IET Conference Proceedings
出版商Institution of Engineering and Technology
页676-681
页数6
卷2020
版本7
ISBN(电子版)9781839535420
DOI
出版状态已出版 - 2020
已对外发布是
活动10th International Conference on Power Electronics, Machines and Drives, PEMD 2020 - Virtual, Online
期限: 15 12月 2020 → 17 12月 2020

会议

会议10th International Conference on Power Electronics, Machines and Drives, PEMD 2020
市Virtual, Online
时期15/12/20 → 17/12/20

学术指纹

探究 'ANALYSIS AND SUPPRESSION OF ON-LOAD EXCITATION WINDING VOLTAGE PULSATING IN PARTITIONED-STATOR HYBRID-EXCITED SWITCHED-FLUX MACHINE' 的科研主题。它们共同构成独一无二的学术指纹。

引用此