TY - JOUR
T1 - An Optical Tracking-Based Robot-Assisted System for Spinal Fixation Rod Bending
AU - Zhang, Weijun
AU - Huang, Yaohui
AU - Li, Xingye
AU - Li, Changsheng
AU - Duan, Xingguang
N1 - Publisher Copyright:
© 2026 John Wiley & Sons Ltd. All rights reserved, including rights for text and data mining and training of artificial intelligence technologies or similar technologies.
PY - 2026/10
Y1 - 2026/10
N2 - Background: In spinal pedicle screw-rod fixation, rod contouring quality influences insertion ease, construct stability, and corrective effect. Conventional bending relies on surgeon experience and is limited by insufficient support, repeated adjustment, and inefficient workflow. Methods: This study developed a tracking-based robot-assisted system for rod bending comprising an acquisition unit, software, and actuator. The system acquires screw-head coordinates, generates target rod shape, and discretises the curve into bending positions, axial rotations, and angles. Results: In five in vitro experiments, five assisted-versus-manual comparisons, and twenty paired cases, planned rods showed high consistency with target curves, with mean angle, rotation, and length errors within acceptable ranges. Assisted bending improved efficiency and reduced placement errors versus manual bending; clinically, the assisted side had a shorter operation time. Conclusions: The system achieves a workflow from acquisition to rod formation, improving quantifiability, consistency, efficiency, and conformity, thus providing a pathway towards automated spinal rod shaping.
AB - Background: In spinal pedicle screw-rod fixation, rod contouring quality influences insertion ease, construct stability, and corrective effect. Conventional bending relies on surgeon experience and is limited by insufficient support, repeated adjustment, and inefficient workflow. Methods: This study developed a tracking-based robot-assisted system for rod bending comprising an acquisition unit, software, and actuator. The system acquires screw-head coordinates, generates target rod shape, and discretises the curve into bending positions, axial rotations, and angles. Results: In five in vitro experiments, five assisted-versus-manual comparisons, and twenty paired cases, planned rods showed high consistency with target curves, with mean angle, rotation, and length errors within acceptable ranges. Assisted bending improved efficiency and reduced placement errors versus manual bending; clinically, the assisted side had a shorter operation time. Conclusions: The system achieves a workflow from acquisition to rod formation, improving quantifiability, consistency, efficiency, and conformity, thus providing a pathway towards automated spinal rod shaping.
KW - digital planning
KW - optical tracking
KW - pedicle screw
KW - robot-assisted spine surgery
KW - rod bending
KW - spinal fixation rod
UR - https://www.scopus.com/pages/publications/105050212307
U2 - 10.1002/rcs.70233
DO - 10.1002/rcs.70233
M3 - Article
C2 - 42731106
AN - SCOPUS:105050212307
SN - 1478-596X
VL - 22
JO - International Journal of Medical Robotics and Computer Assisted Surgery
JF - International Journal of Medical Robotics and Computer Assisted Surgery
IS - 5
M1 - e70233
ER -