跳到主要导航 跳到搜索 跳到主要内容

An Onboard Executable Multitask Network Model for Bioradar-Based ECG Signal Reconstruction Using High-Fidelity DHD Signals

  • Fuze Tian*
  • , Haojie Zhang
  • , Jie Liu
  • , Jingyu Liu
  • , Mingqi Zhao
  • , Kun Qian*
  • , Qinglin Zhao
  • , Bin Hu*
  • , Yoshiharu Yamamoto
  • , Bjorn W. Schuller
  • *此作品的通讯作者
  • Beijing Institute of Technology
  • Lanzhou University
  • Aerospace Central Hospital
  • Chinese Academy of Sciences
  • The University of Tokyo
  • Imperial College London
  • Technical University of Munich

科研成果: 期刊稿件文章同行评审

摘要

Bioradar-based electrocardiogram (ECG) reconstruction shows great promise in replacing traditional contact-based ECG collection methods for noncontact, long-term healthcare applications, such as continuous cardiorespiratory disease monitoring and early warning systems. In this work, we first designed a practical bioradar system for high signal-to-noise ratio (SNR) I/Q baseband signal acquisition, achieving excellent performance with background noise not exceeding 3.18 \mu Vpp and SNRs ranging from 26 to 119 dB. Next, we developed a high-linearity arctangent demodulation method to extract high-fidelity Doppler heartbeat diagram (DHD) signals. Finally, we introduced a lightweight U-Net-based multitask network model for ECG signal reconstruction, which demonstrated performance achieving root mean squared error (RMSE) values of 0.160 and 0.330, root mean absolute error (RMAE) values of 0.261 and 0.400, and Pearson correlation coefficient (PCC) values of 95.17% and 85.26% for two different datasets, respectively. This model is characterized by low computational complexity, with 7.04 M parameters, floating-point operations (FLOPs) of 889.16 M, real-time processing speed of 1.05 s/execution, and low power consumption of 379.5 mW. Moreover, it requires just 29.13 MB of random access memory (RAM) and 10.49 MB of read-only memory (ROM), making it highly suitable for deployment in embedded systems. Experimental results from both public dataset and our own dataset show that the proposed lightweight ECG reconstruction model, when combined with the designed high-fidelity DHD signal acquisition bioradar system, holds significant potential for noncontact healthcare and medical applications.

源语言英语
期刊论文编号4018620
期刊IEEE Transactions on Instrumentation and Measurement
74
DOI
出版状态已出版 - 2025
已对外发布

学术指纹

探究 'An Onboard Executable Multitask Network Model for Bioradar-Based ECG Signal Reconstruction Using High-Fidelity DHD Signals' 的科研主题。它们共同构成独一无二的学术指纹。

引用此