跳到主要导航 跳到搜索 跳到主要内容

Alignment error modeling and control of a double-sided microlens array during precision glass molding

  • Beijing Institute of Technology

科研成果: 期刊稿件文章同行评审

摘要

Double-sided microlens arrays (DSMLAs) include combinations of two single-sided MLAs to overcome positioning errors and greatly improve light transmissivity compared to other types of lenses. Precision glass molding (PGM) is used to fabricate DSMLAs, but controlling alignment errors during this process is challenging. In this paper, a mold assembly was manufactured with a novel combination of materials to improve the alignment accuracy of mold cores during PGM by using the nonlinear thermal expansion characteristics of the various materials to improve the DSMLA alignment accuracy. By establishing a mathematical model of the DSMLA alignment error and a thermal expansion model of the mold-sleeve pair, the relationship between the maximum alignment error of the DSMLA and the mold-sleeve gap was determined. This research provides a method to optimize the mold-sleeve gap and minimize the alignment error of the DSMLA. The measured DSMLA alignment error was 10.56 μm, which is similar to the predicted maximum alignment error. Optical measurements showed that the uniformity of the homogenized beam spot was 97.81%, and the effective homogeneous area accounted for 91.66% of the total area. This proposed method provides a novel strategy to improve the performance of DSMLAs. (Figure presented.).

源语言英语
期刊论文编号48
期刊Microsystems and Nanoengineering
10
1
DOI
出版状态已出版 - 12月 2024

学术指纹

探究 'Alignment error modeling and control of a double-sided microlens array during precision glass molding' 的科研主题。它们共同构成独一无二的学术指纹。

引用此