TY - JOUR
T1 - A time-varying signal processing method for Coriolis mass flowmeter based on adaptive filter
AU - Dan, Feng
AU - Shangchun, Fan
AU - Dezhi, Zheng
N1 - Publisher Copyright:
© The Author(s) 2018.
PY - 2018/1/1
Y1 - 2018/1/1
N2 - In this paper, the normalized least mean square (NLMS) algorithm, a time-varying signal processing method, is employed in a Coriolis mass flowmeter (CFM) to improve its weak anti-jamming capability. Initially, the fundamental principles of the NLMS algorithm adopted in the adaptive filter are analysed. Then, the NLMS algorithm is applied to analyse the signal processing of the CFM at different flow rates in experiments. By comparing several performance indicators and spectrum diagrams from being filtered by the NLMS algorithm and the least mean square (LMS) algorithm, the results indicate that the NLMS algorithm can lead to a better anti-jamming capability and reduce the influence of noise efficiently for the CFM. In addition, the NLMS method has a faster convergence speed and fewer stable errors than the LMS method. Therefore, the NLMS can improve the quality of the output signal of the CFM.
AB - In this paper, the normalized least mean square (NLMS) algorithm, a time-varying signal processing method, is employed in a Coriolis mass flowmeter (CFM) to improve its weak anti-jamming capability. Initially, the fundamental principles of the NLMS algorithm adopted in the adaptive filter are analysed. Then, the NLMS algorithm is applied to analyse the signal processing of the CFM at different flow rates in experiments. By comparing several performance indicators and spectrum diagrams from being filtered by the NLMS algorithm and the least mean square (LMS) algorithm, the results indicate that the NLMS algorithm can lead to a better anti-jamming capability and reduce the influence of noise efficiently for the CFM. In addition, the NLMS method has a faster convergence speed and fewer stable errors than the LMS method. Therefore, the NLMS can improve the quality of the output signal of the CFM.
KW - Adaptive filter
KW - Coriolis mass flowmeter
KW - least mean square
KW - normalized least mean square
KW - signal processing
UR - https://www.scopus.com/pages/publications/85040736441
U2 - 10.1177/0142331216652955
DO - 10.1177/0142331216652955
M3 - Article
AN - SCOPUS:85040736441
SN - 0142-3312
VL - 40
SP - 261
EP - 268
JO - Transactions of the Institute of Measurement and Control
JF - Transactions of the Institute of Measurement and Control
IS - 1
ER -