摘要
Based on the principle of asymmetric split and recombine, this paper has adopted a numerical simulation for the optimized micromixer with dislocation sub-channel to get mixing performance and taken the mixing index as a measurement index. The results show that when Re is ranging from 1 to 80, parameters of geometric structure affect the mixing index of the micromixer obviously and the mixing index is improved if the dislocation sub-channel is set in the major channel. Considering the mixing performance and the pressure drop in the sub-channel, the mixing index of asymmetric split and recombine micromixer with dislocation sub-channel can be increased to 86% when the geometric structure parameter of the dislocation sub-channel is w 3/w 4=1.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 1353-1356 |
| 页数 | 4 |
| 期刊 | Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics |
| 卷 | 33 |
| 期 | 8 |
| 出版状态 | 已出版 - 8月 2012 |
| 已对外发布 | 是 |