跳到主要导航 跳到搜索 跳到主要内容

A shape factor based ultrasonic measurement method for determination of bolt preload

  • Qinxue Pan*
  • , Ruipeng Pan
  • , Meile Chang
  • , Xiaoyu Xu
  • *此作品的通讯作者
  • Beijing Institute of Technology

科研成果: 期刊稿件文章同行评审

摘要

The existing ultrasonic testing models cannot accurately measure bolt preload due to the non-uniform distribution of axial stress in the effective stressed region of bolt and cannot rapidly complete the calibration of detection coefficients due to the difficulty to determine the key parameters such as effective stressed length. In order to eliminate the impact of non-uniform distribution of axial stress on the measurement, realize rapid and accurate calibration of detection coefficients and further improve the measurement accuracy of bolt preload, the concept and determination method of shape factor are proposed. Based on the shape factor, a combination of longitudinal and transverse waves is adopted to establish a mathematical model for measuring the preload applied to a bolt during assembly, avoiding the need to measure ambient temperature. The calculation method of shape factor is obtained by statics simulation of a bolted joint. Through the combination of finite element simulation and experimental calibration, the material factors and temperature factors of 45# steel as well as the shape factors of M20 and M16 bolts are obtained. The experiments show that the relative error of this method is within 5%, which meets the requirements of engineering applications.

源语言英语
文章编号102210
期刊NDT and E International
111
DOI
出版状态已出版 - 4月 2020

指纹

探究 'A shape factor based ultrasonic measurement method for determination of bolt preload' 的科研主题。它们共同构成独一无二的指纹。

引用此