TY - JOUR
T1 - A refraction correction approach for cross-interface stereoscopic particle image velocimetry
AU - Zhu, Kaixin
AU - Liu, Chao
AU - Wu, Yue
AU - Wu, Qin
AU - Huang, Biao
AU - Zheng, Wentao
AU - Wang, Guoyu
N1 - Publisher Copyright:
© 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved. This article is available under the terms of the IOP-Standard License.
PY - 2026/8
Y1 - 2026/8
N2 - In cross-interface stereoscopic particle image velocimetry (SPIV) conducted in water tunnel experiments, placing the calibration target inside water or oil often leads to practical difficulties, including complex installation, contamination of markers, and degraded image quality. To overcome these limitations, this study proposes an external calibration-based SPIV method combined with refraction correction for cross-interface measurements, with calibration performed outside the water tunnel. In the proposed approach, camera calibration is carried out in air, and the camera system is subsequently translated to the measurement position. A ray-tracing model based on Snell’s law is established to describe light propagation through a three-layer medium (air–acrylic–water), and an image remapping algorithm is developed to reconstruct distortion-free virtual images corresponding to a homogeneous medium. The corrected images are then used for standard SPIV processing. The performance of the method is evaluated using both numerical simulation and controlled cylinder wake experiments. The results show that the corrected velocity fields agree well with the reference data, with normalized root mean square error values below 0.2 for all velocity components, demonstrating excellent agreement with the reference data. The proposed method effectively removes refraction-induced distortion and spurious out-of-plane velocity components while preserving flow structures, providing a practical and reliable solution for cross-interface SPIV measurements.
AB - In cross-interface stereoscopic particle image velocimetry (SPIV) conducted in water tunnel experiments, placing the calibration target inside water or oil often leads to practical difficulties, including complex installation, contamination of markers, and degraded image quality. To overcome these limitations, this study proposes an external calibration-based SPIV method combined with refraction correction for cross-interface measurements, with calibration performed outside the water tunnel. In the proposed approach, camera calibration is carried out in air, and the camera system is subsequently translated to the measurement position. A ray-tracing model based on Snell’s law is established to describe light propagation through a three-layer medium (air–acrylic–water), and an image remapping algorithm is developed to reconstruct distortion-free virtual images corresponding to a homogeneous medium. The corrected images are then used for standard SPIV processing. The performance of the method is evaluated using both numerical simulation and controlled cylinder wake experiments. The results show that the corrected velocity fields agree well with the reference data, with normalized root mean square error values below 0.2 for all velocity components, demonstrating excellent agreement with the reference data. The proposed method effectively removes refraction-induced distortion and spurious out-of-plane velocity components while preserving flow structures, providing a practical and reliable solution for cross-interface SPIV measurements.
KW - Snell’s law
KW - cross-interface measurement
KW - external calibration
KW - image remapping
KW - refraction correction
KW - water tunnel experiment stereoscopic particle image velocimetry
UR - https://www.scopus.com/pages/publications/105050411641
U2 - 10.1088/1361-6501/ae9784
DO - 10.1088/1361-6501/ae9784
M3 - Article
AN - SCOPUS:105050411641
SN - 0957-0233
VL - 37
JO - Measurement Science and Technology
JF - Measurement Science and Technology
IS - 34
M1 - 345206
ER -