TY - JOUR
T1 - A Real-Time Liver Deformation Computational Measurement System for Needle Insertion With Ex Vivo Validation
AU - Jiang, Yiping
AU - Fan, Jingfan
AU - Wang, Yuanyuan
AU - Shao, Long
AU - Ai, Danni
AU - Xiao, Deqiang
AU - Fu, Tianyu
AU - Zhang, Jiaju
AU - Zhang, Jinying
AU - Song, Hong
AU - Yang, Jian
N1 - Publisher Copyright:
© 1963-2012 IEEE.
PY - 2026
Y1 - 2026
N2 - Real-time quantification of tissue deformation during needle insertion is important for surgical guidance, yet existing methods often face tradeoffs among biomechanical fidelity, constraint accuracy, and interactive throughput. We propose a unified projective-optimization framework that couples as-rigid-as-possible (ARAP)-based nonlinear elasticity, near-incompressibility, preferred-direction anisotropy, and dynamic needle-tissue interaction (puncture, slip, and friction) within a single alternating direction method of multipliers (ADMM) augmented local-global GPU solver. Puncture constraints are embedded via reference-configuration mapping with constant observation matrices, and an adaptive dual-variable strategy - delayed activation, damped accumulation, and constraint-specific temporal memory - reduces constraint residuals without altering the sparsity pattern of the system matrix, which is solved by GPU-parallel Jacobi-Chebyshev iterations. Evaluation spans numerical comparisons with an implicit FEM reference, robustness tests under large perturbations and motion reversals, and 120-Hz optical tracking of 38 insertions across four ex vivo porcine livers. In the continuous-motion benchmark, the method is 20.5× faster than the tested linear complementarity problem (LCP) implementation. In the ex vivo evaluation, it achieves the best sequence-level means among the four evaluated methods for direction similarity (0.714), motion dynamic time warping (DTW) (1.562 mm), motion local displacement error (MLDE) (0.446 mm), and position RMSE (1.606 mm), with an average simulation-update time of approximately 30 ms per step on the tested GPU. These results support interactive ex vivo surface-deformation tracking under the evaluated conditions.
AB - Real-time quantification of tissue deformation during needle insertion is important for surgical guidance, yet existing methods often face tradeoffs among biomechanical fidelity, constraint accuracy, and interactive throughput. We propose a unified projective-optimization framework that couples as-rigid-as-possible (ARAP)-based nonlinear elasticity, near-incompressibility, preferred-direction anisotropy, and dynamic needle-tissue interaction (puncture, slip, and friction) within a single alternating direction method of multipliers (ADMM) augmented local-global GPU solver. Puncture constraints are embedded via reference-configuration mapping with constant observation matrices, and an adaptive dual-variable strategy - delayed activation, damped accumulation, and constraint-specific temporal memory - reduces constraint residuals without altering the sparsity pattern of the system matrix, which is solved by GPU-parallel Jacobi-Chebyshev iterations. Evaluation spans numerical comparisons with an implicit FEM reference, robustness tests under large perturbations and motion reversals, and 120-Hz optical tracking of 38 insertions across four ex vivo porcine livers. In the continuous-motion benchmark, the method is 20.5× faster than the tested linear complementarity problem (LCP) implementation. In the ex vivo evaluation, it achieves the best sequence-level means among the four evaluated methods for direction similarity (0.714), motion dynamic time warping (DTW) (1.562 mm), motion local displacement error (MLDE) (0.446 mm), and position RMSE (1.606 mm), with an average simulation-update time of approximately 30 ms per step on the tested GPU. These results support interactive ex vivo surface-deformation tracking under the evaluated conditions.
KW - Anisotropy
KW - computational biomechanics
KW - needle insertion measurement
KW - optical tracking validation
KW - projective dynamics (PD)
KW - soft tissue modeling
UR - https://www.scopus.com/pages/publications/105052968779
U2 - 10.1109/TIM.2026.3741997
DO - 10.1109/TIM.2026.3741997
M3 - Article
AN - SCOPUS:105052968779
SN - 0018-9456
VL - 75
JO - IEEE Transactions on Instrumentation and Measurement
JF - IEEE Transactions on Instrumentation and Measurement
M1 - 4016216
ER -