跳到主要导航 跳到搜索 跳到主要内容

A patient-specific study of type-B aortic dissection: Evaluation of true-false lumen blood exchange

  • Duanduan Chen*
  • , Matthias Müller-Eschner
  • , Hendrik von Tengg-Kobligk
  • , David Barber
  • , Dittmar Böckler
  • , Rod Hose
  • , Yiannis Ventikos
  • *此作品的通讯作者
  • Department of Diagnostic and Interventional Radiology
  • Heidelberg University 
  • German Cancer Research Center
  • Institute of Diagnostic
  • University of Bern
  • Department of Cardiovascular Science
  • University of Sheffield
  • Department of Vascular Surgery
  • Department of Mechanical Engineering
  • University College London

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

Background: Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality.Methods: In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models.Results: Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller.Conclusions: The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.

源语言英语
期刊论文编号65
期刊BioMedical Engineering Online
卷12
期1
DOI
出版状态已出版 - 6 7月 2013

学术指纹

探究 'A patient-specific study of type-B aortic dissection: Evaluation of true-false lumen blood exchange' 的科研主题。它们共同构成独一无二的学术指纹。

引用此