摘要
High precision micro displacement measurement framework is fundamental for drilling strain gauges. We replaced the traditional lock-in amplifier method by the linear least square (LLS) based on Duffing chaotic detection (DCD) in drilling strain gauges. Simulation results showed that LLS based on DCD has a relative error 7.7% when SNR= -20.79 dB. It is 410.1% lower than lock-in amplifier method in the detection. Even more, the design and realization of LLS based on DCD is easier than lock-in amplifier method.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 287-293 |
| 页数 | 7 |
| 期刊 | Journal of Advanced Computational Intelligence and Intelligent Informatics |
| 卷 | 20 |
| 期 | 2 |
| DOI | |
| 出版状态 | 已出版 - 2016 |