TY - JOUR
T1 - A fast calibration method for photonic mixer device solid-state array lidars
AU - Zhai, Yayu
AU - Song, Ping
AU - Chen, Xiaoxiao
N1 - Publisher Copyright:
© 2019 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2019/2/2
Y1 - 2019/2/2
N2 - The photonic mixer device (PMD) solid-state array lidar, as a three-dimensional imaging technology, has attracted research attention in recent years because of its low cost, high frame rate, and high reliability. To address the disadvantages of traditional PMD solid-state array lidar calibration methods, including low calibration efficiency and accuracy, and serious human error factors, this paper first proposes a calibration method for an array complementary metal-oxide-semiconductor photodetector using a black-box calibration device and an electrical analog delay method; it then proposes a modular lens distortion correction method based on checkerboard calibration and pixel point adaptive interpolation optimization. Specifically, the ranging error source is analyzed based on the PMD solid-state array lidar imaging mechanism; the black-box calibration device is specifically designed for the calibration requirements of anti-ambient light and an echo reflection route; a dynamic distance simulation system integrating the laser emission unit, laser receiving unit, and delay control unit is designed to calibrate the photodetector echo demodulation; the checkerboard calibration method is used to correct external lens distortion in grayscale mode; and the pixel adaptive interpolation strategy is used to reduce distortion of distance images. Through analysis of the calibration process and results, the proposed method effectively reduces the calibration scene requirements and human factors, meets the needs of different users of the lens, and improves both calibration efficiency and measurement accuracy.
AB - The photonic mixer device (PMD) solid-state array lidar, as a three-dimensional imaging technology, has attracted research attention in recent years because of its low cost, high frame rate, and high reliability. To address the disadvantages of traditional PMD solid-state array lidar calibration methods, including low calibration efficiency and accuracy, and serious human error factors, this paper first proposes a calibration method for an array complementary metal-oxide-semiconductor photodetector using a black-box calibration device and an electrical analog delay method; it then proposes a modular lens distortion correction method based on checkerboard calibration and pixel point adaptive interpolation optimization. Specifically, the ranging error source is analyzed based on the PMD solid-state array lidar imaging mechanism; the black-box calibration device is specifically designed for the calibration requirements of anti-ambient light and an echo reflection route; a dynamic distance simulation system integrating the laser emission unit, laser receiving unit, and delay control unit is designed to calibrate the photodetector echo demodulation; the checkerboard calibration method is used to correct external lens distortion in grayscale mode; and the pixel adaptive interpolation strategy is used to reduce distortion of distance images. Through analysis of the calibration process and results, the proposed method effectively reduces the calibration scene requirements and human factors, meets the needs of different users of the lens, and improves both calibration efficiency and measurement accuracy.
KW - Array complementary metal-oxide- semiconductor photodetector calibration
KW - Electrical analog delay method
KW - Modular lens distortion correction
KW - PMD solid-state array lidar
KW - Photonic mixer device
KW - Pixel point adaptive interpolation
UR - https://www.scopus.com/pages/publications/85061874295
U2 - 10.3390/s19040822
DO - 10.3390/s19040822
M3 - Article
C2 - 30781565
AN - SCOPUS:85061874295
SN - 1424-8220
VL - 19
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
IS - 4
M1 - 822
ER -