基于不同流动时间占比的紧凑式室温磁制冷系统实验研究

  • Rui Li
  • , Jun Shen*
  • , Zhi Peng Zhang
  • , Zhen Xing Li*
  • , Zhao Jun Mo
  • , Xin Qiang Gao
  • , Peng Hai
  • , Qi Fu
  • *此作品的通讯作者
  • Ganjiang Innovation Academy
  • Beijing Institute of Technology

科研成果: 期刊稿件文章同行评审

摘要

Magnetic refrigeration has become a promising new technology to replace conventional vapor-compression refrigeration technology, for it has excellent application characteristics such as the high efficiency, environmental friendliness and structural simplicity. Many studies have been carried out to analyze the various subsystems, but the interaction laws between the systems are not yet clear, and the optimization of each subsystem is still an area of research worth exploring. This work is based on a compact room temperature magnetic refrigeration system developed before, and carries out experimental research on the different flow time ratio to explore the correlation among refrigeration temperature span, cooling capacity, pressure drop, coefficient of performance (COP) and blow fraction under a fixed magnetic field timing. Especially, the effects of different flow time ratios (100%, 80%, 60%) on the system performance are studied under magnetic field timing of 1:4:1:4 and a frequency of 0.45 Hz. The experimental results reveal that a low utilization factor combined with a high flow time ratio can achieve a greater temperature spread, whereas a high utilization factor combined with a high flow time ratio can accomplish a bigger cooling capacity. When the utilization factor is 0.42 and the flow time ratio is 100%, the maximum unloaded cooling temperature span is 26.2 K. Meanwhile, the effects of the utilization factor and flow time ratio on the pressure drop and COP of the regenerator are studied in detail. It is discovered that raising the flow time ratio and reducing the utilization factor both result in a fall in fluid velocity, which leads the pressure to further decrease and the COP to rise. In a word, this research investigates the relationship among cooling temperature span, cooling capacity, pressure drop, COP, and flow time ratio in a fixed magnetic field timing, thus providing the groundwork for future improving the performances of room temperature magnetic refrigeration systems.

投稿的翻译标题Experimental study of compact room temperature magnetic cooling system based on different flow time ratios
源语言繁体中文
文章编号037501
期刊Wuli Xuebao/Acta Physica Sinica
73
3
DOI
出版状态已出版 - 5 2月 2024

关键词

  • coefficient of performance
  • flow time ratio
  • refrigerating capacity
  • refrigeration temperature span

指纹

探究 '基于不同流动时间占比的紧凑式室温磁制冷系统实验研究' 的科研主题。它们共同构成独一无二的指纹。

引用此