TY - JOUR
T1 - Validation of classification system for isolated superior mesenteric artery dissections using image-based computational flow analysis
AU - Zhang, Xuehuan
AU - Chen, Jiale
AU - Qiu, Chenyang
AU - He, Yangyan
AU - Wang, Bing
AU - Zhang, Hongkun
AU - Wu, Ziheng
AU - Chen, Duanduan
N1 - Publisher Copyright:
© 2024
PY - 2024/10
Y1 - 2024/10
N2 - Background and Objective: The isolated superior mesenteric artery dissection (ISMAD) is a rare but potentially fatal vascular disorder. Classifications for ISMAD were previously proposed based on morphometric features. However, the classification systems were not standardized and verified yet. This study conducted computational flow analysis to validate the latest classification system of ISMAD and aid clinical decision-making based on hemodynamic parameters. Methods: 62 patients with ISMAD were included and classified into different types according to false lumen structures (five types, Type I-V) and true lumen patency (two types, Type P and Type S) according to Qiu classification system. Computational fluid dynamics and three-dimensional structural analyses were conducted on the basis of computed tomography angiography datasets. Quantitative and qualitative functional analyses were performed via parameters of interest including volume flow of each minute, pressure drop, pressure gradient, the derivative parameters of wall shear stress such as time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and the relative residence time (RRT). Statistical analyses were conducted among different ISMAD types. Results: TAWSS, OSI and RRT showed significant difference among different types when classified using false lumen structures. In detail, Type IV showed significantly higher TAWSS than other types (p = 0.007). OSI was obviously higher in Type II (p = 0.015). Type IV also presented the lowest RRT (p = 0.005). The pressure drop, pressure gradient, OSI and RRT showed higher value in Type S than that in Type P, demonstrating a statistical significance with p values of 0.017, 0.041, 0.001 and 0.012, respectively. While Type P had larger volume flow than Type S (p = 0.041). Conclusions: The notable differences in hemodynamic features among different types demonstrated the feasibility of Qiu classification system. The evaluation based on hemodynamic simulation might also provide insights into risk identification and guide therapeutic decisions for ISMAD.
AB - Background and Objective: The isolated superior mesenteric artery dissection (ISMAD) is a rare but potentially fatal vascular disorder. Classifications for ISMAD were previously proposed based on morphometric features. However, the classification systems were not standardized and verified yet. This study conducted computational flow analysis to validate the latest classification system of ISMAD and aid clinical decision-making based on hemodynamic parameters. Methods: 62 patients with ISMAD were included and classified into different types according to false lumen structures (five types, Type I-V) and true lumen patency (two types, Type P and Type S) according to Qiu classification system. Computational fluid dynamics and three-dimensional structural analyses were conducted on the basis of computed tomography angiography datasets. Quantitative and qualitative functional analyses were performed via parameters of interest including volume flow of each minute, pressure drop, pressure gradient, the derivative parameters of wall shear stress such as time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and the relative residence time (RRT). Statistical analyses were conducted among different ISMAD types. Results: TAWSS, OSI and RRT showed significant difference among different types when classified using false lumen structures. In detail, Type IV showed significantly higher TAWSS than other types (p = 0.007). OSI was obviously higher in Type II (p = 0.015). Type IV also presented the lowest RRT (p = 0.005). The pressure drop, pressure gradient, OSI and RRT showed higher value in Type S than that in Type P, demonstrating a statistical significance with p values of 0.017, 0.041, 0.001 and 0.012, respectively. While Type P had larger volume flow than Type S (p = 0.041). Conclusions: The notable differences in hemodynamic features among different types demonstrated the feasibility of Qiu classification system. The evaluation based on hemodynamic simulation might also provide insights into risk identification and guide therapeutic decisions for ISMAD.
KW - Classifications of isolated superior mesenteric artery dissections
KW - Computational fluid dynamics
KW - False lumen structure
KW - Functional validation
KW - Isolated superior mesenteric artery dissections
KW - True lumen patency
UR - http://www.scopus.com/inward/record.url?scp=85201209830&partnerID=8YFLogxK
U2 - 10.1016/j.cmpb.2024.108364
DO - 10.1016/j.cmpb.2024.108364
M3 - Article
C2 - 39146760
AN - SCOPUS:85201209830
SN - 0169-2607
VL - 255
JO - Computer Methods and Programs in Biomedicine
JF - Computer Methods and Programs in Biomedicine
M1 - 108364
ER -