Skip to main navigation Skip to search Skip to main content

Upgrade status of beamline 1W1A at Beijing Synchrotron Radiation Facility

  • Zhibang Shen
  • , Lu Zhang
  • , Wangguo Guo
  • , Zhen Wang
  • , Chenxu Liu
  • , Xiaorong Weng
  • , Jinglin Zhou
  • , Hao Liang
  • , Lidan Gao
  • , Shaofeng Wang
  • , Ming Li
  • , Hua Yang
  • , Huanhua Wang
  • , Yu Chen*
  • *Corresponding author for this work
  • CAS - Institute of High Energy Physics
  • University of Chinese Academy of Sciences

Research output: Contribution to journal › Article › peer-review

Abstract

Background: After nearly 20 years of service, beamline 1W1A at the Beijing Synchrotron Radiation Facility undergoes an upgrade. Methods: To keep the beam spot to its designed specifi cations and to address the challenges posed by the increasement of the storage ring beam current, a newly designed bending mechanism for the monochromator is installed. The experimental setup includes updated equipment such as a 6-circle diff ractometer, a 2-dimensional array detector, a closed-cycle cryostat system, and a grazing incidence wide-angle X-ray scattering experiment system. Furthermore, the control system and user data management software were enhanced to support these hardware updates. Results and Conclusion: These updates have provided the beamline with more flexible measurement modes and expanded the dimensionality of experimental data, allowing users to conduct in situ experiments over a wide range of sample temperatures. Benifiting from the upgrades, new experimental methods have become available, resultingin significant improvements in both efficiency and resolution.

Original languageEnglish
Pages (from-to)750-758
Number of pages9
JournalRadiation Detection Technology and Methods
Volume10
Issue number4
DOIs
Publication statusPublished - Aug 2026
Externally publishedYes

Keywords

  • 1W1A beamline
  • Beijing Synchrotron Radiation Facility (BSRF)
  • Monochromator
  • Triangular silicon crystal