Skip to main navigation Skip to search Skip to main content

Ultrasound-Led Multimodality Imaging-Guided Robotic Needle Insertion With Respiratory Phase Consistency in Phantom and Animal Models

  • Fan Xiao
  • , Wen Zhen Ding
  • , Chuan Pang
  • , Qiao Wei Du
  • , Yan Wang
  • , Lu Xin Zhang
  • , Zhao Rui Tian
  • , Jing Yi Bian
  • , Zi Xin Zhang
  • , Dan Ni Ai
  • , Li Nan Dong
  • , Xin Yao Wu
  • , Fang Liu
  • , Fang Yi Liu
  • , Jie Yu
  • , Jian Yang
  • , Ping Liang*
  • *Corresponding author for this work
  • Senior Department of Oncology
  • General Hospital of People's Liberation Army
  • Beijing Institute of Technology

Research output: Contribution to journal › Article › peer-review

Abstract

Objective To evaluate the puncture accuracy and feasibility of TONGMAI, an electromagnetic-tracking–based, ultrasound (US)-led multimodality imaging-guided robotic system using consistency-aware respiratory-guided cognitive fusion, in phantom and animal models. Methods Three experienced and six inexperienced physicians performed needle insertion in static phantom, respiratory phantom, New Zealand white rabbit liver and Guangxi Bama miniature-pig liver experiments using robot assistance, freehand puncture or needle-guide assistance. The primary outcome was real-time US-based puncture accuracy (US-Error). Exploratory robot-assisted punctures of non-hepatic targets (spleen, kidney, pancreas, gallbladder, bladder and lung) in miniature pigs were evaluated for first-attempt success, needle redirection, US-Error when applicable and complications. Results Among experienced physicians, US-Error did not differ significantly among robot assistance, freehand puncture and needle-guide assistance in static phantom, respiratory phantom, rabbit liver or miniature-pig liver experiments (overall p = 0.115, 0.131, 0.124 and 0.397, respectively). With robot assistance, mean US-Error values were 0.35, 0.57, 1.28 and 1.32 mm, respectively. Among inexperienced physicians, robot assistance reduced US-Error versus freehand puncture or needle-guide assistance in both phantom settings and versus freehand puncture in rabbit and miniature-pig liver experiments ( p = 0.003 and p = 0.002, respectively). Under robot assistance, US-Error did not differ significantly between experienced and inexperienced physicians across all settings ( p = 0.110, 0.054, 0.818 and 0.548, respectively). In exploratory non-hepatic punctures, first-attempt success varied by target, with no procedure-related complications. Conclusion TONGMAI supported consistent puncture performance in experienced physicians and improved accuracy in inexperienced physicians under phantom and animal conditions, supporting further development of a US-led multimodality robotic workflow for deformable thoracoabdominal targets.

Original languageEnglish
Pages (from-to)2515-2524
Number of pages10
JournalUltrasound in Medicine and Biology
Volume52
Issue number11
DOIs
Publication statusAccepted/In press - 2026
Externally publishedYes

Keywords

  • Animal model
  • Electromagnetic tracking
  • Fusion imaging
  • Image guidance
  • Needle insertion
  • Percutaneous intervention
  • Phantom
  • Respiratory motion
  • Robotics
  • Ultrasound

Fingerprint

Dive into the research topics of 'Ultrasound-Led Multimodality Imaging-Guided Robotic Needle Insertion With Respiratory Phase Consistency in Phantom and Animal Models'. Together they form a unique fingerprint.

Cite this