Skip to main navigation Skip to search Skip to main content

Transient internal-flow evolution and mass-flow prediction in an inward-opening hydrogen direct injector with dual-row orifices

  • Fengting Sun
  • , Ziman Wang*
  • , Haoxuan Li
  • , Heping Xiang
  • , Yanfei Wen
  • *Corresponding author for this work
  • Beijing Institute of Technology

Research output: Contribution to journal › Article › peer-review

Abstract

Accurate gaseous-fuel delivery in direct-injection hydrogen internal combustion engines depends on the transient flow characteristics of hydrogen injectors. However, the high compressibility of hydrogen induces strong flow transients, challenging conventional quasi-steady predictions and complicating the design of high-performance injectors. This study investigated the transient flow characteristics of an inward-opening hydrogen injector with dual-row orifices using a dynamic-mesh CFD framework. Results revealed a three-stage internal flow evolution during needle opening: a geometric-throat choked-flow stage, a choked-to-unchoked transition stage, and a throat-subsonic stage. An initial gas-dynamic pressure surge occurred early in the choked-flow stage. As backpressure in the sac chamber developed, the sonic structure at the geometric throat disappeared, accompanied by a reconfiguration of internal flow and a directional reversal of mass-flow distribution between dual-row orifices. As injection pressure (Pinj) increased from 10 to 60 bar, the zero-crossing time of the mass-flow split coefficient (Sm) varied by approximately 14 μs. Increasing the sac chamber length enlarged sac volume (Vsac), slowed sac-backpressure buildup, and delayed the transition. Meanwhile, the coefficient of variation of the apparent discharge coefficient (Cd) increased from 8.58% to 10.93%, demonstrating that a constant Cd cannot represent the opening-stage transient response. Ultimately, a mass-flow prediction model was established by integrating separately calibrated Pinj- and Vsac-dependent effects. Across five pressure–geometry CFD assessment cases excluded from calibration, the maximum normalized root mean square deviations were 4.61% for transient mass flow rate and 1.95% for cumulative injected mass.

Original languageEnglish
Article number142720
JournalEnergy
Volume366
DOIs
Publication statusPublished - 30 Nov 2026
Externally publishedYes

Keywords

  • Choked-to-unchoked transition
  • Discharge coefficient
  • Hydrogen direct injector
  • Mass-flow prediction
  • Transient internal flow

Fingerprint

Dive into the research topics of 'Transient internal-flow evolution and mass-flow prediction in an inward-opening hydrogen direct injector with dual-row orifices'. Together they form a unique fingerprint.

Cite this