Skip to main navigation Skip to search Skip to main content

Topology optimization and experimental validation of monolithic torsional metastructures for low-frequency vibration isolation

  • Yue Hu
  • , Dongxian Wang
  • , Hao Zhou
  • , Yun Ma
  • , Haicheng Shao
  • , Qingcun Lai
  • , Pingzhang Zhou
  • , Ivana Kovacic
  • , Rui Zhu*
  • *Corresponding author for this work
  • Beijing Institute of Technology
  • Ltd.
  • Beijing OptFuture Technology Co., Ltd
  • University of Novi Sad

Research output: Contribution to journal › Article › peer-review

Abstract

Shafting systems require compact torsional isolators that can suppress low-frequency vibrations without compromising reliable torque transmission. This study proposes an inverse design framework for monolithic torsional metastructures by integrating topology optimization, conformal mapping, geometric feasibility screening, and nonlinear finite element analysis. Topology optimization is first performed in a uniform rectangular computational domain, after which the optimized topology is conformally mapped onto a sector module and circumferentially replicated to construct the complete annular metastructure. By prescribing the torque–rotation response over a target operating interval, the framework enables the realization of positive, quasi-zero, and negative stiffness characteristics. For quasi-zero stiffness designs, the prescribed operating torque, interval width, and interval center can be independently customized to satisfy different application requirements. The optimized thermoplastic-polyurethane metastructure is fabricated by additive manufacturing and evaluated through both quasi-static and dynamic experiments. The measured torque–rotation and stiffness–rotation responses agree well with the numerical predictions, particularly within the prescribed low-stiffness interval. Dynamic transmissibility tests under two bias-torque conditions further demonstrate initial vibration isolation frequencies of approximately 14 and 7 Hz, respectively, while the theoretical model captures the measured resonance characteristics and the subsequent attenuation trends. These results establish an application-oriented route for designing compact, integrated torsional isolators with programmable torque transmission and low-frequency vibration isolation performance.

Original languageEnglish
Article number115700
JournalThin-Walled Structures
Volume232
DOIs
Publication statusPublished - Jan 2027

Keywords

  • Conformal mapping
  • Monolithic metastructure
  • Quasi-zero stiffness
  • Topology optimization
  • Torsional vibration isolation

Fingerprint

Dive into the research topics of 'Topology optimization and experimental validation of monolithic torsional metastructures for low-frequency vibration isolation'. Together they form a unique fingerprint.

Cite this