Abstract
Environmental temperature of UAV system is crucial for chemical cell component inside. Once the temperature of this chemical cell is over 259 °C and keeps more than 20 min, the high thermal accumulation would result in an explosion, which seriously damage the whole UAV system. Therefore, we develop a micro temperature sensing system for monitoring the temperature of chemical cell thermally influenced by UAV device deployed in a 300 °C temperature environment, which is quite useful for insensitive munitions and UAV safety enhancement technologies.
| Original language | English |
|---|---|
| Article number | 012012 |
| Journal | Journal of Physics: Conference Series |
| Volume | 986 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - 29 Mar 2018 |
| Event | 19th Annual Conference and 8th International Conference of Chinese Society of Micro/Nano Technology, CSMNT 2017 - Dalian, China Duration: 26 Oct 2017 → 29 Oct 2017 |