Skip to main navigation Skip to search Skip to main content

The Protective Mechanism of Polyurea/Aramid Fiber Reinforced Steel Pipes against Implosion-Induced Multi-Physical Field Loads

  • Beijing Institute of Technology

Research output: Contribution to journalConference articlepeer-review

Abstract

This paper studies the protective performance of polyurea-coated steel pipes and aramid fiber-wound steel pipes under the multi-physical field load of internal explosion by combining experiments with numerical simulation. The experimental results show that applying aramid fiber winding has a limited effect on improving the anti-explosion performance of steel pipes, while polyurea-coated steel pipes exhibit better anti-explosion performance under the coupled load of shock waves and fragments. Simulation analysis reveals the protective mechanism of composite structures in terms of energy absorption and stress distribution, providing a theoretical basis for the optimal design of blast-resistant vessels.

Original languageEnglish
JournalSAE Technical Papers
DOIs
Publication statusPublished - 31 Jul 2026
Externally publishedYes
Event10th International Conference on Mechanical Manufacturing Technology and Material Engineering, MMTME 2025 - Shenyang, China
Duration: 19 Sept 202521 Sept 2025

Fingerprint

Dive into the research topics of 'The Protective Mechanism of Polyurea/Aramid Fiber Reinforced Steel Pipes against Implosion-Induced Multi-Physical Field Loads'. Together they form a unique fingerprint.

Cite this