The deflare of holographic combiner and the simplification of ray trace

  • Yonggang Ha*
  • , Liuzhu Ha
  • , Yongtian Wang
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

This paper describes the reason of flare in holographic combiners, and discusses two different methods of ray trace in holographic gratings. It points out that through these two methods one can get the same result when the fringes in grating are parallel to the surface. It can be simplified as follows: a reflective volum holographic grating with a planar interface can be equivalent to a planar mirror and one with a spherical interface can be regarded as a spherical mirror. In this situation, the flare is avoided.

Original languageEnglish
Pages (from-to)435-438
Number of pages4
JournalBeijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology
Volume17
Issue number4
Publication statusPublished - 1997

Keywords

  • Deflare
  • Hologram
  • Holographic combiner
  • Ray trace