Abstract
In order to maximize the spatio-temporal resolution of the scientific grade camera at width-limited ROI, this paper proposes a new hyper-frame-rate imaging method by temporal multiplexing the sub-region of the image sensor. In the system, a dual-axis scanning galvanometer is localized at the relay pupil plane and a high quality scan lens is utilized to form an image-side telecentric path. Following this path can overcome bandwidth waste in the conventional exposure and readout mode, and maintain other performances of image sensors. As a result, the sCMOS camera has performed 432fps over 820 × 700 pixel arrays to record the dynamic heartbeat of zebrafish larvae.
| Original language | English |
|---|---|
| Pages (from-to) | 20813-20822 |
| Number of pages | 10 |
| Journal | Optics Express |
| Volume | 26 |
| Issue number | 16 |
| DOIs | |
| Publication status | Published - 6 Aug 2018 |