Abstract
The wear resistance tests of electroless Ni-P coating which was treated at several different temperatures were studied, and the wear resistance mechanism of E-Ni-P coating was discussed. The results indicate that the hardness of Ni-P coating is the highest with 400°C heat treatment, and the best effect of wear resistance is 600°C heat treatment.
| Original language | English |
|---|---|
| Pages (from-to) | 25-27 |
| Number of pages | 3 |
| Journal | Cailiao Gongcheng/Journal of Materials Engineering |
| Issue number | 8 |
| Publication status | Published - 2000 |
Keywords
- Agglutinate wear
- Electroless plating
- Heat treatment
- Wearing resistance
Fingerprint
Dive into the research topics of 'Study on wearing resistance of electroless Ni-P alloy'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver