Skip to main navigation Skip to search Skip to main content

Study on multi-time scale frequency hierarchical control method and dynamic response characteristics of the generation-grid-load-storage type integrated system under double-side randomization conditions

  • Teng Ma
  • , Ming Jia Li*
  • , Hang Xu
  • , Rui Jiang
  • , Jing Wei Ni
  • *Corresponding author for this work
  • Xi'an Jiaotong University
  • Beijing Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

Under the background of renewable energy infiltration, the generation-grid-load-storage type integrated system presents the double-side randomization characteristics. The multi-time scale interactive response mechanism of multiple subsystems is complicated. The effective dynamic control method is important for the efficient and stable operation of the integrated energy system. In this paper, dynamic characteristic analysis and simulation experiment study of the integrated system under double-side randomization conditions are carried out. First, a multi-time scale dynamic response model of the integrated system coupled with millisecond level on the electrical side and kilo-second level on the thermal side is developed. Second, based on the frequency hierarchical idea, an algorithm of subsystems cooperation is proposed. It is suitable for different distributed energy systems and can be applied to both day-ahead control and intra-day control. Third, the dynamic characteristics of the integrated system under double-side randomization conditions are analyzed. Working conditions include sunny day, cloudy day and rainy conditions on the generation side and industrial load, commercial load and appliance load conditions on the load side. Finally, based on the dynamic experimental platform of the generation-grid-load-storage type integrated system designed and built by our research group, experiment studies are carried out. The results present that the frequency hierarchical control method can reduce the power purchase and abandonment rate. The average of them is reduced by 1.76%, 10.47% and 11.93% under different loads. The maximum error between experimental data and simulation data is 12.32%. The switching process of the vanadium redox flow battery charge and discharge is the main reason of errors.

Original languageEnglish
Article number123436
JournalApplied Energy
Volume367
DOIs
Publication statusPublished - 1 Aug 2024

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Double-side randomization
  • Frequency hierarchical control method
  • Generation-grid-load-storage type integrated system
  • Multi-time scale
  • Simulation experiment

Fingerprint

Dive into the research topics of 'Study on multi-time scale frequency hierarchical control method and dynamic response characteristics of the generation-grid-load-storage type integrated system under double-side randomization conditions'. Together they form a unique fingerprint.

Cite this