Abstract
In this paper, evaluation index system with two levels is established to evaluate energy efficiency of fossil-fuel power plant in a comprehensive and objective way, in order to provide detailed methods for energy-saving and emission reduction. The index system includes five indicators at the first level and two indicators at the second level. Principal component analysis (PCA) model is adopted to comprehensively evaluate energy efficiency of fossil-fuel power units. PCA is a relatively objective evaluation method, which can not only determine weights objectively, but also roundly reflect most information from multiple indicators. The method presented in this paper is implemented on seventeen 1000MW thermal power units. The results obtained agree well with the actual situation and those in the references.
| Original language | English |
|---|---|
| Pages (from-to) | 1093-1098 |
| Number of pages | 6 |
| Journal | Energy Procedia |
| Volume | 61 |
| DOIs | |
| Publication status | Published - 2014 |
| Externally published | Yes |
| Event | 6th International Conference on Applied Energy, ICAE 2014 - Taipei, Taiwan, Province of China Duration: 30 May 2014 → 2 Jun 2014 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Energy efficiency evaluation
- Index system
- Principal component analysis
- Thermal power unit
Fingerprint