TY - JOUR
T1 - Study of zeotropic mixtures of ORC (organic Rankine cycle) under engine various operating conditions
AU - Yang, Kai
AU - Zhang, Hongguang
AU - Wang, Zhen
AU - Zhang, Jian
AU - Yang, Fubin
AU - Wang, Enhua
AU - Yao, Baofeng
PY - 2013/9/1
Y1 - 2013/9/1
N2 - Aiming at the recovery of exhaust energy for a diesel engine, a set of ORC (organic Rankine cycle) system is designed. The characteristics of the exhaust gas under various operating conditions are studied through experiment. Based on experimental results and theoretical calculation, effects of eight kinds of zeotropic mixtures on the performance of ORC system for exhaust energy recovery are discussed for vehicle engine under various operating conditions. Variation of net power output, thermal efficiency, exergy efficiency of ORC system and mass flow rate of zeotropic mixture under various operating conditions of engine is investigated. Two concepts - WHRE (waste heat recovery efficiency) and POIR (power output increasing rate) - are defined and studied. The results show that when the evaporating pressure is 2.0MPa, the net power output of ORC system can reach up to 24.65kW. Using this ORC system, the maximum WHRE is 8.5% and engine power output can be increased by 10.63%.
AB - Aiming at the recovery of exhaust energy for a diesel engine, a set of ORC (organic Rankine cycle) system is designed. The characteristics of the exhaust gas under various operating conditions are studied through experiment. Based on experimental results and theoretical calculation, effects of eight kinds of zeotropic mixtures on the performance of ORC system for exhaust energy recovery are discussed for vehicle engine under various operating conditions. Variation of net power output, thermal efficiency, exergy efficiency of ORC system and mass flow rate of zeotropic mixture under various operating conditions of engine is investigated. Two concepts - WHRE (waste heat recovery efficiency) and POIR (power output increasing rate) - are defined and studied. The results show that when the evaporating pressure is 2.0MPa, the net power output of ORC system can reach up to 24.65kW. Using this ORC system, the maximum WHRE is 8.5% and engine power output can be increased by 10.63%.
KW - Organic Rankine cycle
KW - Various operating conditions
KW - Vehicle diesel engine
KW - Waste heat recovery
KW - Zeotropic mixtures
UR - http://www.scopus.com/inward/record.url?scp=84881103685&partnerID=8YFLogxK
U2 - 10.1016/j.energy.2013.04.074
DO - 10.1016/j.energy.2013.04.074
M3 - Article
AN - SCOPUS:84881103685
SN - 0360-5442
VL - 58
SP - 494
EP - 510
JO - Energy
JF - Energy