Skip to main navigation Skip to search Skip to main content

Study of Nonlinear Scanning Behaviors of PZT-Based Piezoelectric Micromirrors Under DC-Biasing

  • Ke Cao
  • , Qincheng Zheng
  • , Chenyu Bai
  • , Yulang Cheng
  • , Hao Chen
  • , Qian Chen
  • , Huikai Xie*
  • *Corresponding author for this work
  • Beijing Institute of Technology
  • Ministry of Education in China
  • BIT Chongqing Institute of Microelectronics and Microsystems

Research output: Contribution to journal › Article › peer-review

Abstract

Lead zirconate titanate (PZT)-based piezoelectric MEMS micromirrors are highly desirable for their high responsivity, high speed, and low power, but their achievable scan range is fundamentally limited by the large nonlinearities arising from the ferroelectric properties of PZT, especially under high-voltage excitation. In this work, a DC-biasing strategy is proposed to suppress the nonlinearity and extend the usable scan range without the need to modify the device structure or material composition. A piezoelectric micromirror with Z-shaped PZT actuators and a 1 × 1 mm mirror aperture is designed and fabricated. The nonlinear scanning behaviors of the micromirror are systematically studied under various DC bias voltages in both low-frequency and resonant operation modes. Under low-frequency operation, the effects of DC bias are investigated over a voltage range of −20 to + 20 V. Under a −15 V DC bias, the optical scan angle reaches ±6.5◦ at 50 Vpp at 10 Hz, a threefold increase compared with that without DC bias, and achieves a linearity of R2 = 0.997, compared with R2 = 0.887 under the unbiased condition. Under resonant operation, a −15 V DC bias increases the optical scan angle to ±38.3◦ at 30 Vpp excitation and the resonant frequency of 1.35 kHz, corresponding to a 58% enhancement compared with the unbiased condition. The effectiveness of DC bias is strongly dependent on the bias polarity. A bias aligned with the initial polarization shifts the polarization response away from the coercive field and suppresses ferroelectric polarization switching. These results establish DC-biasing as an effective approach for achieving large-angle and high-linearity optical scanning.

Original languageEnglish
JournalIEEE Transactions on Electron Devices
DOIs
Publication statusAccepted/In press - 2026
Externally publishedYes

Keywords

  • DC biasing
  • nonlinear scanning behavior
  • piezoelectric micromirror
  • polarization switching

Fingerprint

Dive into the research topics of 'Study of Nonlinear Scanning Behaviors of PZT-Based Piezoelectric Micromirrors Under DC-Biasing'. Together they form a unique fingerprint.

Cite this