Abstract
According to the logistic regression model based on statistical analysis, the experiments on the minimum ignition energy of different concentrations of nicotinic acid dust-air mixtures have been conducted in the Mike 3 tube by the calculation method of the minimum ignition energy of dust cloud which represented by probability, the volume of Mike 3 tube is 1. 28 L. Utilizing SPSS software, the minimum ignition energy of various concentrations of nicotinic acid dust cloud when the ignition probabilities are 10% and 50% has been calculated. The results show that the minimum ignition energy of nicotinic acid dust cloud has a tendency to first decrease and then increase with increasing concentrations, finally maintain at a certain energy range. Compared with other standard calculations, the viewpoint of ignition as a statistical phenomenon appears to be more consistent with the test data in engineering, it can also meet the needs of different production environments for security control.
| Original language | English |
|---|---|
| Pages (from-to) | 577-584 |
| Number of pages | 8 |
| Journal | Gaoya Wuli Xuebao/Chinese Journal of High Pressure Physics |
| Volume | 28 |
| Issue number | 5 |
| DOIs | |
| Publication status | Published - 15 Oct 2014 |
Keywords
- Dust explosion
- Ignition probability
- Logistic regression
- Minimum ignition energy (MIE)
- Nicotinic acid dust cloud
- Standard of measuring ignition energy
Fingerprint
Dive into the research topics of 'Statistical analysis of minimum electrostatic spark ignition energy of dust cloud'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver