Side-On transition radiation detector (TRD) based on THGEM

Xiwen Liu, Bo Huang, Huanbo Feng, Hongbang Liu*, Wenjin Xie, Xuefeng Huang, Shuai Chen, Jianyu Gu, Xiaochuan Xie, Jin Zhang, Qian Liu, Yongbo Huang, Yongwei Dong, Ming Xu, Enwei Liang

*Corresponding author for this work

Research output: Contribution to journalReview articlepeer-review

13 Citations (Scopus)

Abstract

Purpose: The characteristic that TR energy is proportional to the Lorentz factor provides a way for energy calibration. The High Energy cosmic-Radiation Detection calorimeter can be calibrated in space by the TRD in the future. Method: In order to make the TR signal stand out from the energy loss signal, a new prototype of TRD called Side-On TRD with THGEM has been built. Side-on TRD uses side window incidence and strip readout to reduce the ionization energy registered in the channel where the TR photons are located, which is supposed to improve the detection efficiency of TR. Result and conclusion: The Side-On TRD has been tested at CERN SPS and found the experimental results are significant.

Original languageEnglish
Pages (from-to)257-262
Number of pages6
JournalRadiation Detection Technology and Methods
Volume4
Issue number3
DOIs
Publication statusPublished - 1 Sept 2020
Externally publishedYes

Keywords

  • Radiator
  • THGEM
  • Test beam experiment
  • Transition radiation detector

Fingerprint

Dive into the research topics of 'Side-On transition radiation detector (TRD) based on THGEM'. Together they form a unique fingerprint.

Cite this