Research on performance measurement method of gas leak infrared imaging detection system

Jia Kun Li, Wei Qi Jin*, Xia Wang, Xu Zhang, Yang Liu, Run Qiu Xia

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

As a result of its significant advantages of high efficiency and remote imaging detection, gas leak infrared imaging detection technology has become one of the most effective means to detect gas leaks. This paper focuses on the performance measurement system of gas leak infrared imaging detection system. A novel minimum resolvable gas concentration (MRGC) evaluation method was proposed that was suitable for evaluating the performance of the passive gas leak infrared imaging detection system. The MRGC measurement system was designed and built. The measurement result, using ethylene as the target gas, and the minimum resolvable temperature difference (MRTD) curve were in good agreement, which sufficiently demonstrated the effectiveness of the MRGC performance evaluation method.

Original languageEnglish
Pages (from-to)630-634
Number of pages5
JournalBeijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology
Volume36
Issue number6
DOIs
Publication statusPublished - 1 Jun 2016

Keywords

  • Gas leak detection
  • Infrared imaging
  • Measurement system
  • Minimum resolvable gas concentration (MRGC)
  • Performance evaluation