T1 - Research on Non-Contact Detection Method of Deteriorated Insulators Based on Magnetic Field Measurement
AU - Zhou, Zhiguo
AU - He, Zhengyan
AU - Zhou, Xuehua
N1 - Publisher Copyright:
© 2024 IEEE.
PY - 2024
Y1 - 2024
N2 - Deteriorated insulators seriously affect the normal operation of the power system, for this reason, this paper proposes a non-contact deteriorated insulator detection method based on magnetic field measurement. Firstly, the insulator space magnetic field distribution characteristics are analyzed and a method to separate the magnetic field signal of degraded insulators is proposed, and then on this basis, a high-voltage experimental platform of 110kV insulator strings is constructed, and the method of this paper is verified experimentally. The experimental results show that the magnetic field method can realize the non-contact detection of degraded insulators at a distance of 1m away; the spatial magnetic field of lightly polluted insulator strings has a significant difference in the effective value of the spatial magnetic field compared with that of ultra-lightly polluted insulator strings; and the incremental change of the spatial magnetic field caused by the zero value of different.
AB - Deteriorated insulators seriously affect the normal operation of the power system, for this reason, this paper proposes a non-contact deteriorated insulator detection method based on magnetic field measurement. Firstly, the insulator space magnetic field distribution characteristics are analyzed and a method to separate the magnetic field signal of degraded insulators is proposed, and then on this basis, a high-voltage experimental platform of 110kV insulator strings is constructed, and the method of this paper is verified experimentally. The experimental results show that the magnetic field method can realize the non-contact detection of degraded insulators at a distance of 1m away; the spatial magnetic field of lightly polluted insulator strings has a significant difference in the effective value of the spatial magnetic field compared with that of ultra-lightly polluted insulator strings; and the incremental change of the spatial magnetic field caused by the zero value of different.
KW - leakage current
KW - magnetic field measurement
KW - non-contact detection
UR - https://www.scopus.com/pages/publications/85208047833
U2 - 10.1109/AIPS64124.2024.00120
DO - 10.1109/AIPS64124.2024.00120
M3 - Conference contribution
AN - SCOPUS:85208047833
T3 - Proceedings - 2024 International Conference on Artificial Intelligence and Power Systems, AIPS 2024
SP - 552
EP - 558
BT - Proceedings - 2024 International Conference on Artificial Intelligence and Power Systems, AIPS 2024
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2024 International Conference on Artificial Intelligence and Power Systems, AIPS 2024
Y2 - 19 April 2024 through 21 April 2024