TY - JOUR
T1 - Real-time reference A-line subtraction and saturation artifact removal using graphics processing unit for high-frame-rate Fourier-domain optical coherence tomography video imaging
AU - Huang, Yong
AU - Kang, Jin U.
PY - 2012/7
Y1 - 2012/7
N2 - Variations in the spectral shape and the amplitude of the optical coherence tomography (OCT) signal and reference cause fixed-pattern noise and light reflected from a highly specular surface might cause saturation artifacts. In real-time video-rate OCT imaging, these effects make the OCT video image appear unstable and difficult to view. To eliminate these problems, we implemented real-time reference A-line subtraction and saturation detection and correction on standard Fourier-domain optical coherence tomography (FD-OCT) video imaging frame-by-frame. This real-time OCT data processing method eliminates the need for the physical reference measurement procedure and automatically detects and corrects saturated A-scans if there is any within one frame. This technique is also robust to the reference and signal amplitude variations, and provides higher signal-to-noise ratio compared to the normal fixed-reference subtraction method. To implement an effective interventional OCT imaging system, the technique was integrated along with other graphics processing unit-based OCT processing techniques [resampling, dispersion compensation, fast Fourier transform, log-scaling, and soft-thresholding]. The real-time fixed-pattern artifact-free FD-OCT imaging was achieved at 70 frames/s for a frame size of 1000 (lateral) by 1024 (axial) pixels. The theoretical maximum processing and rendering rate was measured to be 266,000 A-scans/s.
AB - Variations in the spectral shape and the amplitude of the optical coherence tomography (OCT) signal and reference cause fixed-pattern noise and light reflected from a highly specular surface might cause saturation artifacts. In real-time video-rate OCT imaging, these effects make the OCT video image appear unstable and difficult to view. To eliminate these problems, we implemented real-time reference A-line subtraction and saturation detection and correction on standard Fourier-domain optical coherence tomography (FD-OCT) video imaging frame-by-frame. This real-time OCT data processing method eliminates the need for the physical reference measurement procedure and automatically detects and corrects saturated A-scans if there is any within one frame. This technique is also robust to the reference and signal amplitude variations, and provides higher signal-to-noise ratio compared to the normal fixed-reference subtraction method. To implement an effective interventional OCT imaging system, the technique was integrated along with other graphics processing unit-based OCT processing techniques [resampling, dispersion compensation, fast Fourier transform, log-scaling, and soft-thresholding]. The real-time fixed-pattern artifact-free FD-OCT imaging was achieved at 70 frames/s for a frame size of 1000 (lateral) by 1024 (axial) pixels. The theoretical maximum processing and rendering rate was measured to be 266,000 A-scans/s.
UR - http://www.scopus.com/inward/record.url?scp=84866953636&partnerID=8YFLogxK
U2 - 10.1117/1.OE.51.7.073203
DO - 10.1117/1.OE.51.7.073203
M3 - Article
AN - SCOPUS:84866953636
SN - 0091-3286
VL - 51
JO - Optical Engineering
JF - Optical Engineering
IS - 7
M1 - 073203