TY - JOUR
T1 - Rapid determination of all element in MAPbI3 thin films using laser induced breakdown spectroscopy
AU - Wang, Xianshuang
AU - Wan, Sushu
AU - He, Yage
AU - Qiu, Suling
AU - Ma, Xiao
AU - Wazir, Nasrullah
AU - Tian, Yuxi
AU - Liu, Ruibin
N1 - Publisher Copyright:
© 2021 Elsevier B.V.
PY - 2021/4
Y1 - 2021/4
N2 - The photoelectric efficiency and degradation mechanism of methylammonium lead iodide (MAPbI3) thin film based device is highly determined by elemental composition and localized distribution. However, the total element analysis of perovskite films is still a huge challenge with current analytical techniques. The quantitative analysis of all elements are tried based on Laser Induced Breakdown Spectroscopy (LIBS) for the first time. The distribution of stoichiometric ratios of plumbum to carbon ([Pb]/[C]) on the films is determined by calibration-free LIBS, which illustrates locally elemental inhomogeneity and stoichiometric ratio deviation. Furthermore, low Limits of Detection (LoD) are obtained based on calibration procedure with a high determination coefficient R2 = 0.99, especially a relatively low LoD of 1.76 ppm and 39.54 ppm for nitrogen and hydrogen are respectively realized, which are lower than that of ever reported results. Interestingly, after laser ablation, a fluorescence decay phenomenon in and around the laser-ablated crater is observed. Our results provide a feasibility qualitative analytical methods based on LIBS to realize reliable determination of all elements in the MAPbI3 thin film with high accuracy and fast speed.
AB - The photoelectric efficiency and degradation mechanism of methylammonium lead iodide (MAPbI3) thin film based device is highly determined by elemental composition and localized distribution. However, the total element analysis of perovskite films is still a huge challenge with current analytical techniques. The quantitative analysis of all elements are tried based on Laser Induced Breakdown Spectroscopy (LIBS) for the first time. The distribution of stoichiometric ratios of plumbum to carbon ([Pb]/[C]) on the films is determined by calibration-free LIBS, which illustrates locally elemental inhomogeneity and stoichiometric ratio deviation. Furthermore, low Limits of Detection (LoD) are obtained based on calibration procedure with a high determination coefficient R2 = 0.99, especially a relatively low LoD of 1.76 ppm and 39.54 ppm for nitrogen and hydrogen are respectively realized, which are lower than that of ever reported results. Interestingly, after laser ablation, a fluorescence decay phenomenon in and around the laser-ablated crater is observed. Our results provide a feasibility qualitative analytical methods based on LIBS to realize reliable determination of all elements in the MAPbI3 thin film with high accuracy and fast speed.
UR - https://www.scopus.com/pages/publications/85101236080
U2 - 10.1016/j.sab.2021.106123
DO - 10.1016/j.sab.2021.106123
M3 - Article
AN - SCOPUS:85101236080
SN - 0584-8547
VL - 178
JO - Spectrochimica Acta - Part B Atomic Spectroscopy
JF - Spectrochimica Acta - Part B Atomic Spectroscopy
M1 - 106123
ER -