Abstract
A new derivate of β-cyclodextrin with peptides was prepared, where the peptides were obtained from the enzymolysis of bovine serum albumin (BSA) in the presence of trypsin. The derivate was bonded with silica gel to give a novel chiral stationary phase for high performance liquid chromatography (HPLC). The chiral separations of (±) 1-phenylpropanol was investigated using an re-phase RP-HPLC system with this column. Several important HPLC conditions were studied including variability of gradient time of pH value of phosphate buffer, ionic intensity, and mobile phase velocity. The chiral recogniztion mechanism and the repetition on chiral separate of 1-phenyl-propanol on the new stationary phase were probed. Experiments shown that the best condition of 1-phenylpropanol on the new chiral stationary phase (CSP) is mobile phase, 60 mmol/L phosphate, gradient pH buffer, 1 min pH 5.6, 10 m in pH 6.4, flow rate, 0.5 mL/m in.
| Original language | English |
|---|---|
| Pages (from-to) | 646-649 |
| Number of pages | 4 |
| Journal | Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology |
| Volume | 27 |
| Issue number | 7 |
| Publication status | Published - Jul 2007 |
Keywords
- 1-phenylpropanol
- High performance liquid chromatography
- Peptide-CD-silica gel chiral stationary phase