Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution

Quan Jie Jia*, Yu Chen, Gang Li, Xiao Ming Jiang

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

7 Citations (Scopus)

Abstract

Employing the approximation theory based on refraction and the definition of the total point-spread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different source-to-sample and sample-to-detector distances, which actually means different spatial resolutions of the imaging system. The experiments were carried out with the Beamline 4W1A imaging setup at the Beijing Synchrotron Radiation Facility for simple model and insect samples. The results show that to obtain clear phase-contrast images of biologic tissues for the X-ray in-line imaging setup, with determined parameters such as the size of the X-ray source, the pixel size of the detector and the fixed source-to-sample distance, there is a range of optimized sample-to-detector distances. The analysis method discussed in this article can be helpful in optimizing the setup of X-ray in-line phase-contrast imaging.

Original languageEnglish
Pages (from-to)267-274
Number of pages8
JournalChinese Physics C
Volume36
Issue number3
DOIs
Publication statusPublished - Mar 2012
Externally publishedYes

Keywords

  • edge-contrast enhancement
  • spatial resolution
  • X-ray phase contrast imaging

Fingerprint

Dive into the research topics of 'Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution'. Together they form a unique fingerprint.

Cite this