Abstract
By ignoring the temperature change in the direction of oil-film thickness and regarding the calculation of oil-film temperature as a two-dimensional problem, the temperature distribution of oil-film in the plunger pair of an axial plunger pump is studied with numerical method. With the distribution of oil-film thickness given, the oil-film temperature distribution of plunger pair is obtained by the joint-solution of viscosity-temperature and viscosity-pressure relations, Reynolds equation and energy equation. The results show that the temperature rise calculated with two-dimensional adiabatic model is closer to tested value than traditional analytic method and the calculated temperature distribution well agrees to test results.
| Original language | English |
|---|---|
| Pages (from-to) | 781-784 |
| Number of pages | 4 |
| Journal | Qiche Gongcheng/Automotive Engineering |
| Volume | 35 |
| Issue number | 9 |
| Publication status | Published - Sept 2013 |
| Externally published | Yes |
Keywords
- Adiabatic condition
- Plunger pair
- Temperature distribution
Fingerprint
Dive into the research topics of 'Numerical analysis on the temperature distribution of oil-film in plunger pair'. Together they form a unique fingerprint.Cite this