Note: Erosion of W-Ni-Fe and W-Cu alloy electrodes in repetitive spark gaps

  • Jiawei Wu
  • , Ruoyu Han
  • , Weidong Ding
  • , Aici Qiu
  • , Junping Tang

Research output: Contribution to journalArticlepeer-review

11 Citations (Scopus)

Abstract

A pair of W-Ni-Fe and W-Cu electrodes were tested under 100 kA level pulsed currents for 10 000 shots, respectively. Surface roughness and morphology characteristics of the two pairs of electrodes were obtained and compared. Experimental results indicated cracks divided the W-Cu electrode surface to polygons while the W-Ni-Fe electrode surface remained as a whole with pits and protrusions. Accordingly, the surface roughness of W-Ni-Fe electrodes increased to ∼3 μm while that of W-Cu electrodes reached ∼7 μm at the end of the test. The results reveal that the W-Ni-Fe alloy has a better erosion resistance and potential to be further applied in spark gaps.

Original languageEnglish
Article number026103
JournalReview of Scientific Instruments
Volume89
Issue number2
DOIs
Publication statusPublished - 1 Feb 2018
Externally publishedYes

Fingerprint

Dive into the research topics of 'Note: Erosion of W-Ni-Fe and W-Cu alloy electrodes in repetitive spark gaps'. Together they form a unique fingerprint.

Cite this