TY - JOUR
T1 - Nonlinear Material Behavior Analysis under High Compression Pressure in Dynamic Conditions
AU - Zahid, Muhammad Zubair
AU - Butt, Shahid Ikramullah
AU - Iqbal, Tauqeer
AU - Ejaz, Syed Zohaib
AU - Faping, Zhang
N1 - Publisher Copyright:
© 2017 Muhammad Zubair Zahid et al.
PY - 2017
Y1 - 2017
N2 - Gun chamber pressure is an important parameter in proofing of ammunition to ensure safety and reliability. It can be measured using copper crushers or piezoelectric sensor. Pressure calculations in copper crusher method are based on linear plastic deformation of copper after firing. However, crusher pressure deformation at high pressures deviates from the corresponding values measured by piezoelectric pressure transducers due to strain rate dependence of copper. The nonlinear deformation rate of copper at high pressure measurements causes actual readings from copper crusher gauge to deviate from true pressure values. Comparative analysis of gun chamber pressure was conducted for 7.62 × 51 mm ammunition using Electronic Pressure, Velocity, and Action Time (EPVAT) system with piezoelectric pressure transducers and conventional crusher gauge. Ammunitions of two different brands were used to measure chamber pressure, namely, NATO standard ammunition and non-NATO standard ammunition. The deformation of copper crushers has also been simulated to compare its deformation with real time firing. The results indicate erratic behavior for chamber pressure by copper crusher as per standard deviation and relative spread and thus prove piezo sensor as more reliable and consistent mode of peak pressure measurement. The results from simulation, cost benefit analysis, and accuracy clearly provide piezo sensors with an edge over conventional, inaccurate, and costly method of copper crusher for ballistic measurements due to its nonlinear behavior.
AB - Gun chamber pressure is an important parameter in proofing of ammunition to ensure safety and reliability. It can be measured using copper crushers or piezoelectric sensor. Pressure calculations in copper crusher method are based on linear plastic deformation of copper after firing. However, crusher pressure deformation at high pressures deviates from the corresponding values measured by piezoelectric pressure transducers due to strain rate dependence of copper. The nonlinear deformation rate of copper at high pressure measurements causes actual readings from copper crusher gauge to deviate from true pressure values. Comparative analysis of gun chamber pressure was conducted for 7.62 × 51 mm ammunition using Electronic Pressure, Velocity, and Action Time (EPVAT) system with piezoelectric pressure transducers and conventional crusher gauge. Ammunitions of two different brands were used to measure chamber pressure, namely, NATO standard ammunition and non-NATO standard ammunition. The deformation of copper crushers has also been simulated to compare its deformation with real time firing. The results indicate erratic behavior for chamber pressure by copper crusher as per standard deviation and relative spread and thus prove piezo sensor as more reliable and consistent mode of peak pressure measurement. The results from simulation, cost benefit analysis, and accuracy clearly provide piezo sensors with an edge over conventional, inaccurate, and costly method of copper crusher for ballistic measurements due to its nonlinear behavior.
UR - http://www.scopus.com/inward/record.url?scp=85029800795&partnerID=8YFLogxK
U2 - 10.1155/2017/3616932
DO - 10.1155/2017/3616932
M3 - Article
AN - SCOPUS:85029800795
SN - 1687-5966
VL - 2017
JO - International Journal of Aerospace Engineering
JF - International Journal of Aerospace Engineering
M1 - 3616932
ER -